An a-to-z guide to x-ray inspection: understandingx-ray inspection theory is essential when...

By Bernard, David
Publication: Circuits Assembly
Date: Saturday, December 1 2007

Ed: This is the first of a two-part article.

X-ray inspection systems offer PCB manufacturers a way to inspect solder joints and locations in a non-destructive manner with products that cannot be inspected optically. For example, x-ray inspection permits examination of the solder joint

quality of area array packages such as BGAs and CSPs. It can also be used to investigate the wire attachment quality within semiconductor device packages and very fine pitch SMT components. Inspection applications are almost endless with a high quality x-ray machine. Without x-ray inspection, the only alternative method would be destructive removal of the part in question with subsequent optical investigation. However, the optical approach renders the product and device useless and can destroy the area that needs to be investigated, potentially eradicating vital analytical clues that can indicate the cause of process defects or failures.

[FIGURE 1 OMITTED]

X-ray inspection has conventionally been used for development and field-failure analysis. More recently, x-ray's advantages have become more important for both production quality and production process control applications. Increased use of area array packages, chip scale packages and flip chips demands it. AOI is ineffective on these devices because their solder joints are hidden from view.

Several different types of x-ray inspection systems include laminography and computerized tomography (CT). This article will focus on the most common type: two-dimensional x-ray inspection.

2-D x-ray inspection systems are essentially x-ray microscopes. X-rays are produced from a tube, passing through the sample and then into an x-ray image-capture device (Figure 1). The image-capture device converts the x-rays it receives into visible images typically displayed on a PC monitor. Any object, or material, within the sample that is of higher density than the surroundings will absorb more of the x-rays in that location. As a result, fewer x-rays will pass through the sample at that location, so fewer will hit the capture device at that point, thus casting a darker shadow on the detector. A typical x-ray image produced by an x-ray inspection system has solder locations, device terminations and copper tracks appearing dark compared with the laminated circuit board in a PCB. The greater the density difference between the materials, the more clearly the contrast will appear on the x-ray image. For example, voids, or air bubbles, within BGA solder balls are much less dense than the surrounding solder, and as such can be easily distinguished (Figure 1).

Sample manipulation in the x, y and z directions within the x-ray inspection system is necessary to permit movement to different locations on the test sample (x and y-plane movements) and to change the height of the sample relative to the x-ray tube position (z-direction). Sample movement in the z-direction changes the magnification achieved by the system. For example, moving the sample closer to the x-ray tube increases the magnification (Figure 2).

Magnification and Image Quality

The magnification level a particular x-ray inspection system can provide is called the geometric magnification. This is a ratio of

Distance between the x-ray tube focal spot and the detector = A

Distance between the x-ray tube focal spot and the sample a

Historically there have been two main tube types used in 2-D x-ray inspection systems. These tubes are called closed or sealed tubes, and open or demountable tubes. Further information on the various types of x-ray tubes used for inspection, and the effects different tubes have on the inspection capabilities such as on magnification and resolution, can be found within numerous literature.

In some x-ray machine specifications, the term "system magnification" or "total magnification" is used in place of geometric magnification to indicate the systems capability. This term indicates the ratio of the sample size as presented on the operator's viewing screen compared to its actual size. Therefore, if a substantially larger monitor or flat panel display was used on an existing x-ray system, its system magnification would be substantially increased as the x-ray image would appear larger on-screen, but the geometric magnification and image quality of that system would be unchanged (Figure 3).

[FIGURE 2 OMITTED]

The geometric magnification values used in x-ray system specifications always assume the test sample is extremely thin, permitting its placement as close as possible to the x-ray tube. However, as the sample grows in thickness, and its proximity to the x-ray tube reduced, then the actual geometric magnification for a specific sample may be substantially less. The best approach to confirm acceptable magnification for a particular application is to try real samples within different x-ray systems.

Determining which additional capabilities and functions an x-ray system needs to optimize inspection for a particular application requires answers to a number of questions. Whatever the answers generated to define and satisfy an x-ray inspection system suitable for a particular application, it is strongly recommended that the system provide a top-down view and oblique angle views. The system should also provide a substantially high level of grayscale sensitivity in the image capture device.

Oblique angle viewing. When limited to inspection of solder bumps from directly above the sample, the main mass of the solder ball will mask the observation of subtle variations that might occur in the interfacial areas between the solder ball and device on one side, and the pad on the other. These interfacial areas will indicate if the joint quality is acceptable. By viewing the joint at an oblique (slanted) angle, and equally important at several different angles, the interference from the solder ball bulk can be reduced or eliminated. This permits the solder ball shape and any interfacial variations, including voids, to be clearly visualized.

Imagine a good BGA solder ball joint as a soccer ball sandwiched between two flat pieces of wood. Compared with the oblique angle view, a top down view limits the information that can be obtained. The larger the oblique angle, the better the separation between the bulk of the ball and the interface.

In a 2-D x-ray system, all layers within the board are shown at the same time. Ideally, oblique angle views should be available without any loss of available geometric magnification. If oblique angle views are not available, then the bulk of the feature or a device or component on the second side of a board may obscure the object under investigation. Consequently, as devices continue to shrink, any lack of magnification will again compromise the analytical value.

[FIGURE 3 OMITTED]

[FIGURE 4 OMITTED]

Oblique viewing capability can be achieved by moving the system image-capture device, in some way, into an oblique angle relative to the plane of the x-ray tube and sample. This replaces the traditional method of tilting the sample relative to the plane of the x-ray tube and image capture device. By moving the image-capture device for oblique views, the sample need not be moved away from the x-ray tube to prevent collisions, as would be required in the traditional method. Therefore, there will be no loss in available geometric magnification when an oblique view is needed, unlike with traditional methods (Figure 4).

Enhanced grayscale sensitivity of the image-capture device is required so that in smaller and less dense objects, the x-ray system has better capacity to visually separate and very small density differences in the samples. This permits detection of more subtle variations and faults. The images use this enhanced sensitivity to highlight faults within the samples.

Ed.: Part two will be published in January.

Dr. David Bernard is product manager x-ray systems at Dage Precision Industries (dage-group.com); d.bernard@dage-group.com.

Dr. David Bernard

In addition, make sure to read these articles:

  • New angles on X-ray inspection: X-ray systems can be used in-line to identify errors...
  • Until a few years ago electrical testing and visual inspection were deemed sufficient for quality control of bare-board PCB manufacturing, with x-ray inspection reserved only ......
  • Minimizing radiation to components: filters during x-ray can reduce radiation without...
  • X-ray inspection has become ever more important for checking product quality as it allows investigation within optically hidden areas, such as the quality of post-solder ......
  • X-ray inspection system.
  • The SVX-2000 x-ray inspection system combines colorlgrayscale optical inspection and x-ray inspection in one package. The system provides increased inspection capabilities through improvements to both ......
  • '5-axis' x-ray inspection.
  • JewelBox 90T and 70T real-time x-ray inspection systems permit examination of internal solder joints and bonds in advanced packages. Said to provide geometric magnification ......
  • Nissan Advanced Crash Laboratory Begins Operations.
  • GARDENA, Calif. -- Nissan Motor Co., Ltd. (NASDAQ:NSANY), announced today that it has begun operations at its newly constructed Nissan Advanced Crash Laboratory (NACL) ......
  • ADVISORY/Talking Book, Counterfeit Money Detectoramong Innovations Going Public; Drexel...
  • Assignment Editors ADVISORY...for Wednesday (May 31) --(BUSINESS WIRE) WHAT: Nine Teams of Drexel engineering seniors present their final projects for judging tomorrow in the Senior ......
  • Forged-body needle valves
  • F10 Series forged-body needle valves feature working pressures up to 10,000 psig. Features include straight, 90-deg, and oblique-angle configurations and a non-rotating, hardened needle for ......
  • X-ray inspection system.
  • The TIGER (FXS-160.40) x-ray system now offers true x-ray intensity (TXI) control to assist operators in identifying production anomalies with consistent x-ray images. Unlike conventional ......
  • Without Consent
  • Helen West, a lawyer for London's Crown Prosecution Service, deals mostly with cases of rape and the often hapless victims she has to persuade to ......
  • The Best American Essays 2002
  • Eighteenth edition of the annual known for its high standards lives up to its predecessors. Editor Gould, who died in May, was himself an accomplished ......
  • Submicron x-ray inspection.
  • The XiDAT XD7500NT digital x-ray inspection system is said to have submicron inspection capability and sealed tube technology. Provides oblique angle viewing of up to ......
  • X-ray system recognizes submicron features
  • The XiDAT XD7500NT digital x-ray inspection system from Dage Precision Industries offers a submicron inspection capability and features sealed-tube technology to minimize maintenance. Its manipulator ......
  • 950 nm digital x-ray.
  • XiDAT XD7500 digital x-ray system for PCB assembly has 950-nm feature recognition and oblique angle views of up to 70[degrees] for any position 360[degrees] around ......
  • Night Vision
  • If Dita Legends resembles a nightclub, that's no accident. A long, narrow space outfitted in dark colors and edgy materials, the West Hollywood eyewear store ......